Code listed limitations on maximum dryer exhaust duct length can seriously impact practical dryer location options. Typical code requirements state that dryer exhaust ducts be no longer than 25 feet, minus allowances for duct bends. Fortunately, there is a code exception that allows for greater duct lengths when listed by the dryer manufacturer ...

Learn More

Hot Products

Taking Technology Innovation As Core Strategy, Our Has Established Beneficiation Machinery Research Institute, Crushing Machinery Research Institute, Powder Grinding Machinery Research Institute And Construction Equipment Research Institute.

Your demand

Contact Information

Zhengzhou High-tech Zone, China

[email protected]

  • Section 504 Clothes Dryer Exhaust 504.1 Installation.
    Section 504 Clothes Dryer Exhaust 504.1 Installation.

    2019-11-14Code to be fire-resistance rated, unless such duct is constructed of galvanized steel or aluminum of the thickness specified in Section 603.3 and the fire-resistance rating is maintained in accordance with the International Building Code. 504.3 Cleanout. Each vertical riser shall be provided with a means for cleanout. 504.4 Exhaust installation ...

    Get A Quote
  • Venting Building Code | Dryerell
    Venting Building Code | Dryerell

    In an effort to reduce the number of dryer fires over 15,500 per year in the US alone most building code has strict guidelines for properly venting a dryer. Every foot of duct run reduces airflow efficiency and small radius elbows have an even greater impact. The Dryer-Ell

    Get A Quote
  • Multiple Dryer Venting In Single Duct  Hvactalk
    Multiple Dryer Venting In Single Duct Hvactalk

    2014-12-24Multiple dryer venting in single duct ... I think the code requirements are involved enough that running 3 individual ducts would be easier and more cost effective. ... would need a spearate exhaust fan on duct, and interlocks on all the dryers to start fan when any one dryer running. Col 323 questions asked, answers received, ignorance abated ...

    Get A Quote
  • Fantech RVF4XLDB10 Exterior Wall Mounted Dryer
    Fantech RVF4XLDB10 Exterior Wall Mounted Dryer

    The electrical supply to the booster fan is connected in series through a normally open terminal on the switch. A pressure tap is connected to a nipple on the side of the switch. When the dryer begins operation, positive pressure in the duct causes the switch diaphragm to expand closing the circuit to the booster fan.

    Get A Quote
  • Where Can I Find Information On Dryer Venting Codes
    Where Can I Find Information On Dryer Venting Codes

    2019-8-20Rick Harpenau In-O-Vate Technologies, Inc Jupiter, FL 33477 561-743-8696

    Get A Quote
  • Dryer Vent Safety Installation Guide Clothes Dryer
    Dryer Vent Safety Installation Guide Clothes Dryer

    Clothes dryer exhaust vent draft booster fan - Dryer Exhaust Duct Power Ventilator DEDPVs Some respected manufacturers recommend adding a draft booster fan Dryer Exhaust Duct Power Ventilator DEDPV on long clothes dryer vent duct runs to reduce lint accumulation and to overcome duct length restrictions, overheating, and possible fire hazards.

    Get A Quote
  • CLOTHES DRYER VENTING  Prospex
    CLOTHES DRYER VENTING Prospex

    2016-6-15of the Arizona BTR that inspectors observe and report on dryer venting. 2006 IRC requirements regarding clothes dryer vent duct systems these requirements do not apply to listed and labeled condensing ductless clothes dryers. For the purposes of this article, we will review the inspection of clothes dryer venting systems by

    Get A Quote
  • The Dryer Vent Requirements For Residential Housing Fall
    The Dryer Vent Requirements For Residential Housing Fall

    2008-8-27The Dryer Vent Requirements For Residential Housing Fall Under The California Uniform Mechanical Code Sections 504.1 and 504.3 Section 504.3.1 Dryer venting shall terminate on the exterior of the building and will have a back draft damper flapper.

    Get A Quote
  • ICC Code Solutions | Jencofan
    ICC Code Solutions | Jencofan

    2020-2-132012 IRC Ventilation Requirements and SP Solutions. The Ventilation Requirements of the IRC are found in Chapter 15 Exhaust Systems. We have provided a brief overview of each section requiring ventilation for the full code visit www.iccsafe.org. Section M1502 Clothes Dryer Exhaust

    Get A Quote
  • Clothes Dryer Exhaust Venting Questions Answers
    Clothes Dryer Exhaust Venting Questions Answers

    John Cranor Website www.house-whisperer.com , ASHI certified home inspector house-whisperer.com in Richmond, VA, can be reached by email to johncranorverizon.net or by telephone at 804-873-8534.Technical review, email, 12012 8 The Facts About Clothes Dryer Exhaust Systems, John Cranor, the ASHI Reporter, April 2005,American Society of Home Inspectors, Inc., 932 Lee

    Get A Quote
  • South Eastern Massachusetts Dryer Vent Installation
    South Eastern Massachusetts Dryer Vent Installation

    When your dryer vent system is damaged, dont wait for the problems to pile up Dryer Vent Wizard of South Eastern MA is prepared to help now. Booster Fan Installation. A booster fan is recommended in dryer vent lines that are 35 ft or longer without bends in

    Get A Quote
  • Dryer Venting Tjernlund.Com
    Dryer Venting Tjernlund.Com

    2012-3-1When a dryers vent is more than twenty-five equivalent feet or if it is experiencing long drying time, you may need to add a dryer booster fan to improve the dryer venting system. The Dryer Duct Booster can also reduce the potential fire hazard associated with lint buildup. The Dryer Duct Booster maintains proper exhaust velocity in duct runs ...

    Get A Quote
  • Chapter 5 Exhaust Systems California Mechanical
    Chapter 5 Exhaust Systems California Mechanical

    An ASHRAE 10-percent to 15-percent efficiency filter shall be permitted for an HVAC unit meeting the 2013 California Energy Code having 60,000 Btuh 17.6 kW or less capacity per fan coil, if the energy use of the air delivery system is 0.4 Wcfm 848 Wm 3 s or less at design air flow.

    Get A Quote
  • Lint Trap  Continental Fan
    Lint Trap Continental Fan

    For duct runs in unheated spaces, Continental Fan recommends insulated duct to reduce the effects of condensation. An LT100 Lint Trap may be installed between the dryer and the booster fan to reduce lint build-up and maintenance on the fan. Complete the job with our full line of fan accessories and controls.

    Get A Quote
  • Dryer Duct Building Codes For MA Condo House
    Dryer Duct Building Codes For MA Condo House

    2011-12-22I have a condo where the dryer duct runs for nearly 32 feet before exiting the house. I opened it up today and there was tons of lint. Funny thing is, there is a wall only about 4 feet from the dryer where the duct could be run out, but it would be on the front of the building.

    Get A Quote
  • Vent Installation  Dryer Vent Guardian Dryer Vent
    Vent Installation Dryer Vent Guardian Dryer Vent

    Dryer Vent Installation For many years, there were very little, or no code requirements for dryer venting. Sadly, this resulted in thousands of home fires across North America. Often, when our technicians inspect a dryer exhaust duct, they find ducts made of unsafe materials that are no longer considered safe for use. Therefore, these ducts

    Get A Quote
  • Installation Instructions For Model DBF4XLT Dryer Exhaust
    Installation Instructions For Model DBF4XLT Dryer Exhaust

    2014-1-10dryer and the clothes dryer booster fan if the booster fan is located less than 15 linear feet 4.6 linear meters from the exhaust of the clothes dryer. Electrical Connection DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. The DBF4XLT is provided with a

    Get A Quote
  • Dryer Booster Fans | Residential Fans | Hvacdirect.Com
    Dryer Booster Fans | Residential Fans | Hvacdirect.Com

    Dryer Booster Fans Large selection with low, wholesale prices designed to save you money while providing top quality performance.

    Get A Quote
  • Dryer Vent Booster Fan Building Code
    Dryer Vent Booster Fan Building Code

    Dryer Vent Booster Fan Building Code. 2014-10-31building code04cleanoutach vertical riser shall be provided with a means for cleanout04exhaust installation dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft dampercreens shall not be installed at the duct termination ducts.

    Get A Quote
  • ICC Code Solutions | Jencofan
    ICC Code Solutions | Jencofan

    2020-2-132012 IRC Ventilation Requirements and SP Solutions. The Ventilation Requirements of the IRC are found in Chapter 15 Exhaust Systems. We have provided a brief overview of each section requiring ventilation for the full code visit www.iccsafe.org. Section M1502 Clothes Dryer Exhaust

    Get A Quote
  • Dryer Exhaust System US Draft Co
    Dryer Exhaust System US Draft Co

    DES Dryer Exhaust System. The Dryer Exhaust System DES maintains a constant pressure in the clothes dryer exhaust system. Designed with EC-Flow Technology, the DES takes advantage of US Draft Co. bi-directional pressure transducer and proprietary PID technology to rapidly respond to varying manifold pressures due to load changes in the clothes dryer exhaust system.

    Get A Quote
  • Indianapolis Area Dryer Vent Installation Repair |
    Indianapolis Area Dryer Vent Installation Repair |

    When your dryer vent system is damaged, dont wait for the problems to pile up Dryer Vent Wizard of Central Indiana is prepared to help now. Booster Fan Installation. A booster fan is recommended in dryer vent lines that are 35 ft or longer without bends in order to

    Get A Quote
  • Proper Clothes Dryer Venting | Building America
    Proper Clothes Dryer Venting | Building America

    Per the requirements of the International Residential Code, Section M1502 2009-2018 IRC, the clothes dryer exhaust duct should be made of galvanized steel or galvanized aluminum rigid or semi-rigid metal with a smooth interior finish and a duct diameter of 4 inches.

    Get A Quote
  • Gecommerciallaundry.Com Venting Specifications For
    Gecommerciallaundry.Com Venting Specifications For

    2007-11-25Each dryer duct must have a 4 diameter backdraft damper, adjusted so that it will just close with the dryer inoperative. This will prevent the exhaust and lint of one dryer from going into another dryer and its room. The duct system for each individual dryer must meet the turn and length requirements as noted on next page.